Insulation Resistance Tester

Insulation Resistance Tester

Insulation Resistance Tester is designed to insulation resistance of components and equipment. Using the constant voltage test method, its voltage output range is 25~1000V and the maximum output current is 1.8mA. It has contact abnormality detection and short circuit abnormality test function, the minimum test period is only 50mS.

Piyush Technologies offeres Insulation Resistance Tester. Built-in a high-efficiency switching power supply, device internal heat is small and no heat dissipation. So the chassis can be made sealed to avoid dust. The sensitive parts select low-temperature drift components and strengthen moisture-proof treatment. The whole PCB using patch design technology has a strong shockproof performance.

SMPS design, low heat

Moisture-proof coating, low-temperature drift components

Sealed case, dustproof keys

Fast and efficient inspection
The fastest inspection time of HT9920 insulation tester is 50ms (0.05s), which achieves the fastest speed in the industry and achieves the purpose of shortening inspection time.

Features:

  • Adopting switching power supply principle, max constant current output 1.8mA and voltage output range 25~1000V,with step 1V
  • High test speed, minimum test cycle only 50mS
  • Unique anomaly detection function, the instrument can detect the test leads abnormality and the abnormal contact of the measured object, avoiding the open circuit misjudgment
  • Short-circuit detection function effectively detect short-circuit conditions and avoid
  • Direct application of high-voltage breakdown of defective products and to misjudgment
  • Automatic discharge, the instrument will automatic discharge after the test completed. HT9920 adopts non-contact constant current discharge, fast, efficient and reliable
  • Various interfaces are equipped, external I/O, analog, LAN ,RS232 interface
  • Double-click trigger to prevent high-voltage electronic shock accidents caused by false triggers. Users can set the double-click action to trigger the test.
  • Analog output. Analog output port of the instrument output results. After each test is completed, output 0~4V analog voltage value corresponding to the test result. There are two types of voltage output, one is full range output and the other is single range output.
  • Quickly charge and discharge the capacitive load
  • Stable measurement without additional shielded wire.
  • Parts of the device under test contact check function to avoid misjudgment in open circuit.
  • Short circuit detection before test to prevent high voltage breakdown.
  • Continuous test mode, PASS termination mode, FAIL termination mode, and forced termination mode.
  • Various interfaces, suitable for pipeline sorting.